11.3.4 Error type E or F
1
2
3
4
9a
9b
Fig. 53: Error type E, diagram
1
2
3
4
5
Fig. 54: Error type F, diagram
6.0.0.0
E000
Fig. 55: Acknowledging error type E or F
Installation and operating instructions Wilo-Stratos GIGA, GIGA-D, GIGA B
Error type E (Fig. 53):
5
6
7
8
Error type F (Fig. 54):
If type E or F errors occur, proceed as follows to acknowledge (Fig. 55):
• To change to the menu mode, press the operating button.
Menu number <6.0.0.0> flashes on the display.
12.3
• Press the operating button again.
Menu number <6.0.0.0> appears steady on the display.
The error is acknowledged, and the status page is displayed.
NOTICE:
The error will be acknowledged automatically if the cause of the error
is eliminated.
Program step/
Contents
query
1
• Error code is displayed
• Pump goes into emergency operation
2
Error counter is incremented
3
Error matrix AC or HV?
4
SSM is activated
5
Error criterion fulfilled?
6
Error acknowledged?
7
Error matrix HV and > 30 min?
8
SSM is activated
9a
End; auto control (twin-head pump) resumes
End; auto control (single pump) resumes
9b
Yes
No
Program step/
Contents
query
1
Error code is displayed
2
Error counter is incremented
3
Error criterion fulfilled?
4
Error acknowledged?
5
End; auto control resumes
Yes
No
(11-22kW)
English
129