12. HOSE REEL CALIBRATION

Go to the configuration menu, two consecutive access codes are required.
The first one is .... (four dots) and then the system will ask for another one
which is NEXU. You will go to the following screen:
Then go to "Calibration" and follow the next steps.
Introduce the hose reel you want to calibrate.
Introduce the volume of the calibrated measure in which the calibration.
Press "Start".
Deliver the quantity that was set in the "Requested Quantity" field.
Once you have reached the quantity defined in the "Requested Quantity"
field, please press Enter.