Electrical installation

Mains connection 230 V/240 V

Stop!
l
Controller type E82EVxxxK 2B must only be connected to a mains voltage of 3/PE AC
100 ... 264 V. Higher mains voltages will destroy the controller!
l
The discharge current to PE is > 3.5 mA. EN 50178 requires a fixed installation.
Double PE connection required.
3 PE AC 230/240 V
45Hz -0%...65Hz +0% 100 V -0%...264 V +0%
L1
L2
L3
N
PE
X1.1 PE L1
L2
E82EVXXXK B 2
Abb. 1-9
E82EV752K2B
Operation only with mains choke
X1.1/+ UG,
DC supply (DC-bus operation - see Operating Instructions)
X1.1/-UG
Fuses and cable cross-sections
Type
Type
mains
mains
E82EV302K2B
3/PE AC
E82EV402K2B
100 ... 264 V;
E82EV552K2B
45 ... 65 Hz
E82EV752K2B
1)
Use UL-approved cables, fuses and fuse holders only.
UL fuse: voltage 240 V, tripping characteristic "H" or "K5"
2)
All-current sensitive residual current circuit breaker for the use with E82EVxxxK4B00x
3)
All-current sensitive residual current circuit breaker for the use with E82EVxxxK4B20x
4)
Flexible cable can only be connected using pin end connectors.
5)
Mains circuit breakers only when using mains chokes.
Observe national and regional regulations (e. g. VDE 0113, EN 60204)
Please observe the following when using e.l.c.bs:
E.l.c.bs must only be installed between mains supply and controller.
l
E.l.c.bs can trip incorrectly because of
l
– capacitive leakage currents of the cable shields during operation (especially with long,
shielded motor cables),
– simultaneous connection of several controllers to the mains supply,
– use of additional RFI filters.
12
L3
+UG -UG
Installation to EN 60204-1
Fuse
E.l.c.b.
M20 A
B20 A
M25 A
B25 A
M35 A
B32 A
M35 A
-
EDK82EV3 DE/EN/FR 2.0
0,7...0,8 Nm
6.2...7.1 lb-in
6 mm / 0.24 in
Installation to UL
L1, L2, L3, PE
Fuse
2
[mm
]
4
20 A
4)
6
25 A
5)
4)
6
35 A
4)
6
35 A
X1.1
8200vec065
1)
FI
FI
L1, L2, L3, PE
[AWG]
12
≥ 300 mA
10
2)
10
≥ 30 mA
10
L
3)