2

Technical data

Conformity
Approvals
Max. permissible motor cable length
Max. permissible motor cable length
(without additional output choke)
Environmental conditions
Temperature ranges
Temperature ranges
Permissible installation height
Permissible installation height
Vibration resistance
Permissible mounting positions
Free space
Discharge current to PE (EN 50178)
Enclosure (EN 60529)
Protection measures against
Insulation of control circuits
1)
For compliance with EMC regulations, the permissible cable lengths must be changed.
Type
Type
Power
Power
E82EV302K2B
3.0 kW 3/PE AC 230/240 V
E82EV402K2B
4.0 kW
E82EV552K2B
5.5 kW
3)
E82EV752K2B
7.5 kW
E82EV302K4B
3.0 kW
E82EV402K4B
4.0 kW
E82EV552K4B
5.5 kW
E82EV752K4B
7.5 kW
3)
E82EV113K4B
11.0 kW
E82EV302K4B
3.0 kW
E82EV402K4B
4.0 kW
E82EV552K4B
5.5 kW
E82EV752K4B
7.5 kW
3)
E82EV113K4B
11.0 kW
1)
for operation without mains choke
2)
for rated mains voltage and chopper frequency of 8 kHz
3)
Operation only with mains choke
8
CE
UL 508C
1)
)
shielded:
unshielded:
Class 3K3 to EN 50178
(without condensation, average relative humidity 85 %)
transport
storage
operation
operation
0 ... 4000 m amsl
above 1000 m amsl the rated output current is to be reduced by 5
%/1000 m
Acceleration resistant up to 0.7 g
vertical
≥ 100 mm below and above
side-by-side mounting without distance in between
> 3.5 mA
IP 20
Short circuit, earth fault (earth-fault protected during operation,
limited earth-fault protection during power up), motor stalling,
motor overtemperature (input for PTC or thermal contact, I
monitoring)
Safe mains disconnection:
Double basic insulation according to EN 50178
Mains voltage
Mains voltage
3/PE AC 230/240 V
100 V 0 % ... 264 V + 0 %
100 V - 0 % ... 264 V + 0 %
45 Hz 0 % ¼ 65 Hz + 0 %
45 Hz - 0 % ¼ 65 Hz + 0 %
DC 140 V - 0 % ... 370 V + 0 %
3/PE AC 400 V
3/PE AC 400 V
320 V - 0 %
320 V - 0 % ... 550 V + 0 %
550 V + 0 %
45 Hz - 0 % ¼ 65 Hz + 0 %
45 Hz - 0 %
65 Hz + 0 %
DC 450 V - 0 % ... 775 V + 0 %
DC 450 V - 0 %
775 V + 0 %
3/PE AC 500 V
3/PE AC 500 V
320 V - 0 % ... 550 V + 0 %
320 V - 0 %
550 V + 0 %
45 Hz - 0 % ¼ 65 Hz + 0 %
45 Hz - 0 %
65 Hz + 0 %
DC 450 V - 0 % ... 775 V + 0 %
DC 450 V - 0 %
775 V + 0 %
EDK82EV3 DE/EN/FR 2.0
Low-Voltage Directive (73/23/EEC)
Underwriter Laboratories (File-No. E132659)
Power Conversion Equipment as of version
E82EVxxxKxBxxxXX VA 14
With rated mains voltage and
With rated mains voltage and
50 m
chopper frequency of 8 kHz
100 m
-25 °C ... + 70 °C
-25 °C ... + 60 °C
-10 °C ... + 55 °C
above + 40 °C the rated output current is to be
reduced by 2.5 %/°C
Mains
Mains
Output current
1)
1)
current
I
r
15.6 A
12.0 A
21.3 A
16.5 A
29.3 A
22.5 A
28.0 A
28.6 A
9.0 A
7.3 A
12.3 A
9.5 A
16.8 A
13.0 A
21.5 A
16.5 A
21.0 A
23.5 A
7.2 A
5.8 A
9.8 A
7.6 A
13.4 A
10.4 A
17.2 A
13.2 A
16.8 A
18.8 A
f
f
2
t
2)
Weight
Weight
I
(60 s)
max
18.0 A
2 9 kg
2.9 kg
24.8 A
33.8 A
3 6 kg
3.6 kg
42.9 A
11.0 A
2.9 kg
2.9 kg
14.2 A
19.5 A
24.8 A
3 6 kg
3.6 kg
35.3 A
11.0 A
2.9 kg
2.9 kg
14.2 A
19.5 A
24.8 A
3.6 kg
3 6 kg
35.3 A
L