7
Commissioning
Code table (excerpt)
Code
No.
Name
C0170 ¿ Configuration
TRIP reset
C0171 Delay for
auto-TRIP reset
C0182* Integration time
S–ramps
C0183* Diagnostics
C0183 Diagnostics
C0196* ¿ Activation of
auto DCB
auto–DCB
C0239 Lowest frequency
limit
C0265* ¿ Configuration
motor
potentiometer
38
Possible settings
Lenze
Selection
-0-
-0-
TRIP reset by mains switching,
LOW–signal at X3/28, via function
module or communication module
-1-
like -0- and additional auto TRIP
reset
-2-
TRIP reset through mains switching,
function module or communication
module.
-3-
TRIP reset by mains switching
0.00
0.00
0.00
0.00
0
No fault
102
TRIP active
104
Message "Overvoltage (
"Undervoltage (
142
Pulse inhibit
151
Quick stop active
161
DC-injection brake active
250
Warning active
-0-
-0-
Auto-DCB active if
output frequency < threshold C0019
-1-
Auto-DCB active if
output frequency < threshold C0019
and setpoint < threshold C0019
-480.0
-480.00
0
-0-
Start value = power off
-3-
-1-
Start value = C0010
-2-
Start value = 0
-3-
Start value = power off
QSP, if UP/DOWN = LOW
-4-
Start value = C0010
QSP, if UP/DOWN = LOW
-5-
Start value = 0
QSP, if UP/DOWN = LOW
EDK82EV3 DE/EN/FR 2.0
s
,
{s}
60.00
{s}
50.00
O O O O U U U U
)" or
L L L L U U U U
)" active
{Hz}
480.00 The value does not fall
IMPORTANT
TRIP reset via
l
function module or
communication
communication
module with C0043,
C0410/12 or C0135
C0410/12 or C0135
bit 11.
Auto TRIP reset after
l
the time set under
the time set under
C0171.
C0182 = 0.00: Linear
l
ramp function
generator operation
C0182 > 0.00:
l
S-shaped ramp
function generator
(smooth)
Only display
Only display
below limit
independently of the
setpoint.
Start value: output
l
frequency which is
approached with Tir
(C0012) when the
(C0012) when the
mains is switched on
and the motor
potentiometer is
potentiometer is
activated:
– "Power off" = act.
value if mains is off
value if mains is off
– "C0010": min.
output frequency
from C0010
– "0" = output
0
output
frequency 0 Hz
C0265 = -3-, -4-,
l
-5-:
– QSP reduces the
QSP reduces the
motor
potentiometer
setpoint along the
QSP ramp (C0105)
L

Publicité