LEDs at the controller (operating status display)
LED
green
a
a
blinking
fast blinking
Fault messages at the keypad or in the parameter setting program Global Drive Control
Display
1)
Keypad PC
n n n n o o o o e e e e r r r r
0
c c c c c c c c r r r r
71
a
a
c c c c e e e e 0 0 0 0
61
a
c c c c e e e e 1 1 1 1
62
a
c c c c e e e e 2 2 2 2
63
a
c c c c e e e e 3 3 3 3
64
a
c c c c e e e e 4 4 4 4
65
a
c c c c e e e e 5 5 5 5
66
a
L
Fault detection and elimination
red
a
blinking every second
blinking every 0.4 seconds
Fault
Cause
No fault
-
System fault
Strong interferences on control
cables
Ground or earth loops in the
wiring
Communication
Faulty transmission of control
fault to AIF
commands via AIF
Communication
CAN-IN1 object receives faulty
fault to CAN-IN1
data or communication is
with Sync control
interrupted
Communication
CAN-IN2 object receives faulty
fault to CAN-IN2
data or communication is
interrupted
Communication
CAN-IN1 object receives faulty
fault to CAN-IN1
data or communication is
with event or time
interrupted
control
BUS-OFF
Controller has received too
many incorrect telegrams via
(many
the system bus and has been
communication
disconnected
faults occurred)
CAN Time-Out
For remote parameter setting via
system bus (C0370):
Slave does not answer.
Communication monitoring time
exceeded.
For operation with module in
FIF:
Internal fault
Operating status
Controller enabled
Mains switched on and automatic start inhibited
Controller inhibited
Fault active, check under C0161
Undervoltage switch-off
Motor parameter identification
EDK82EV3 DE/EN/FR 2.0

Faulty operation

Remedy
-
Shield control cables
Insert the communication module
into the hand terminal
Plug-in connection - bus module
l
ó
Check FIF
Check transmitter
l
Increase monitoring time under
l
C0357/1 if necessary
Plug-in connection - bus module
l
ó
Check FIF
Check transmitter
l
Increase monitoring time under
l
C0357/2 if necessary
Plug-in connection - bus module
l
ó
Check FIF
Check transmitter
l
Increase monitoring time under
l
C0357/3 if necessary
Check whether bus terminator
l
available
Check screen contact of the
l
cables
Check PE connection
l
Check bus load, if necessary,
l
reduce the baud rate
Check system bus wiring
l
Check system bus configuration
l
Contact Lenze
?