Code
No.
Name
2
C0120 I
t switch-off
C0140* Added frequency
setpoint
(NSET1-NADD)
C0142 ¿ Start condition
C0143* ¿ Selection of
flying-restart
flying restart
C0144 ¿ No temperature
depending
chopper
chopper
frequency
derating
[C0148]* Motor parameter
identification
C0156* Current threshold
C0161* Actual fault
C0162* Last fault
C0163* Last but one fault
C0164* Last but two fault
C0168* Actual fault
L
Possible settings
Lenze
Selection
0
0
-480.00
-0-
Automatic start inhibited
-1-
Flying restart not active
-1-
Automatic start, if X3/28 = HIGH
Flying restart not active
-2-
Automatic start inhibited
Flying-restart circuit active
-3-
Automatic start, if X3/28 = HIGH
Flying-restart circuit active
-0-
-0-
Max. output frequency (C0011) ... 0
Hz
-1-
Last output frequency ... 0 Hz
-2-
Frequency setpoint addition
(NSET1-NOUT)
-3-
Act. process controller value
(C0412/5) addition (PCTRL1-ACT)
-1-
-0-
No temperature depending chopper
frequency derating
-1-
Automatic chopper frequency
derating at J
-0-
-0-
Identification not active
-1-
Start identification
V/f-rated frequency (C0015), slip
l
compensation (C0021) and
motor stator inductivity (C0092)
are calculated and saved.
The motor stator resistance
l
(C0084) = total resistance of
motor cable and motor is
measured and saved
0
0
EDK82EV3 DE/EN/FR 2.0
Commissioning
Code table (excerpt)
{%}
200 C0120 = 0: I
{Hz}
480.00
- 5 °C
max
{%}
150
7
IMPORTANT
2
t switch-off
not active
Selection via function
l
j
of the keypad or
the parameter
channel
Non-volatile saving of
l
the value (i.e. active
after mains
switching); value is
added to the main
setpoint
Start after LOW-HIGH
level change at X3/28
Start after LOW-HIGH
level change at X3/28
Motor speed selected for
the indicated range
the indicated range
The corresponding value
is input after controller
is input after controller
enable.
bl
Only with cold motors!
1. Inhibit controller, wait
until drive is in
standstill
2. Enter the correct
motor data under
motor data nder
C0087, C0088,
C0089, C0090,
C0091 (see motor
nameplate).
3. C0148 = set 1 by
v
4. Enable controller
The identification
c
– starts,
Off
– takes approx. 30 s
– is completed when
c
is on again
5. Controller inhibit
Display history buffer
contents
contents
Keypad: three-digit,
Keypad: three-digit,
l
l
alpha numerical fault
detection
detection
9371BB keypad:
9371BB keypad:
l
l
LECOM fault number
37