ULTRAFLEX
ALERT ID
REQUEST
0
Timeout1 port fault
8
1
Timeout1 stbd fault
Over current peak electric motor port
0
fault
9
Over current peak electric motor stbd
1
fault
EHPS port EEPROM parameters missing
0
or corrupted
10
EHPS stbd EEPROM parameters miss-
1
ing or corrupted
0
EHPS port motor speed fault
11
1
EHPS stbd motor speed fault
0
EHPS port end of life fault
12
1
EHPS stbd end of life fault
0
EHPS port init fault
13
1
EHPS stbd init fault
0
EHPS port CAN bus message missing
14
1
EHPS stbd CAN bus message missing
0
EHPS program memory corrupted
15
1
EHPS program memory corrupted
0
EHPS watchdog fault
16
1
EHPS watchdog fault
0
EHPS port overtemp warning
30
1
EHPS stbd overtemp warning
MESSAGE
ELECTRO-HYDRAULIC POWER UNIT WARNINGS
INTERVENTION
Check that the bypass valve on the electrohydraulic
power unit is closed.
Check that the oil level is low.
Contact the Technical Service.
Check that the bypass valve on the electrohydraulic
power unit is closed.
Check that the oil level is low.
Contact the Technical Service.
Contact the Technical Service.
Contact the Technical Service.
Contact the Technical Service.
Contact the Technical Service.
Contact the Technical Service.
Contact the Technical Service.
Contact the Technical Service.
Contact the Technical Service.
Check the CAN bus PORT connection.
Check the good condition of the cable and CAN cable
connections (red tape) to the Tee.
Contact the Technical Service.
Check the CAN bus STBD connection.
Check the good condition of the cable and CAN cable
connections (green tape) to the Tee.
Contact the Technical Service.
Check the CAN bus PORT connection.
Check the good condition of the cable and CAN cable
connections (red tape) to the Tee.
Contact the Technical Service.
Check the CAN bus STBD connection.
Check the good condition of the cable and CAN cable
connections (green tape) to the Tee.
Contact the Technical Service.
Replace the electrohydraulic control unit.
Replace the electrohydraulic control unit.
Replace the electrohydraulic control unit.
Replace the electrohydraulic control unit.
Check that the place where the electrohydraulic
control unit is installed is sufficiently cooled.
Contact the Technical Service.
Check that the place where the electrohydraulic
control unit is installed is sufficiently cooled.
Contact the Technical Service.
INTEGRA SYSTEM
User manual
page 25