4. Installation

4.1 Selecting Mounting Location

 Do not mount the inverter on flammable construction materials.
 Mount on a solid surface.
 IMEON may possibly be noisy during operation which would be disagreable if installed in a
living room area.
 The temperature may cause a reduction of power due to the excessive heating.
 Install the IMEON at eye level in order to allow the LCD display to be read at all times.
 Dusty conditions may impair the performance of this inverter.
 Do not switch IMEON on, if the temperature or the humidity are out of the authorized limits.
The ambient temperature should be between -20°C and +50°C and relative humidity should
FR
be between 0% and 90% to ensure optimal operation.
 For proper air circulation to dissipate heat, allow a clearance of approx. 20 cm to the side and
FR
EN
approx. 50 cm above and below the IMEON.
 For proper operation of this inverter, please use appropriate cables for grid connection.
For the appropriate functioning of this inverter, please use adapted cables cross- section (taking
into account the length of cables, the mode of installation, the impedances, currents and voltage).
 The recommended installation position (vertical) is to be adhered to.
 Installation must be adapted to the weight and the dimensions of the inverter.
 This inverter is designed with IP20 for indoor applications only.

4.2 Mounting Unit

WARNING: This inverter is heavy! Please be careful when removing it from the package.
 Installation to the wall should be implemented with the proper screws so that the solar inverter
can be easily attached to the wall. After that, the device should be bolted on securely.
 Choose an appropriate place of support.
WARNING: Suitable for mounting on concrete or other non-combustible surface only! Take into
account a space of ventilation between the case and the wall.
96
IMEON 9.12
Screw to be used:
- 15 à 18 mm
- Ø M10
Guide de montage / Installation guide IMEON 9.12 – Rev A.8