WARNING: Do not switch the circuit breaker when the IMEON is under load, it can damage the
inverter.
Step 7 : To communicate between the inverter and a lithium battery, it is necessary to make a RJ45
cable wired as follows on the IMEON side.
See chapter "7.4 Battery configuration" in order to set up your battery.

4.6 PV Module (DC) Connection

WARNING: It's very important for system safety and efficient operation to use appropriate cable
for PV module connection
WARNING: Do NOT touch the connectors of the inverter when the photovoltaic modules are
exposed to sunlight. The PV modules can generate a DC voltage in the inverter and a risk of
electric shock.
WARNING: Before connecting inverter to PV modules, install separately a DC circuit breaker
between inverter and PV modules. Install protections (circuit breakers, fuses and lightning
conductors) according to existing standards.
Manuel d'installation / Installation guide IMEON 9.12 – Rev A.8
IMEON 9.12
FR
FR
EN
101