Connecting the data lines on the bus coupler

The following must be observed if you do not use pre-
assembled plug connections and cables:
Use 5-wire, shielded lines.
W
Connect the shield on both sides of the bus cable directly to
W
the plug housing (EMC housing). This protects data lines
from terminal interferences.
Use cables with a wire cross-section of at least 0.34 mm
W
Wire connections X71 and X72 in accordance with the
W
following table.
Table 5:
Assignment X71 (DDL IN) and X72 (DDL OUT), M12, A-coded
Contact
Assignment
Pin 1
24 V line for electronics/sensors
Pin 2
24 V line for valves (U
Pin 3
0 V line
Pin 4
DDL H signal line
Pin 5
DDL L signal line
Knurled nut/
Shield
thread
How to connect the data lines on the bus coupler if using the
bus coupler as an intermediate station:
1. Connect the incoming DDL line to X71 (1).
2. Connect the outgoing DDL line with the next module using
the X72 output (2).
How to connect the data lines on the bus coupler, if using the
bus coupler as an individual or last station:
1. Connect the incoming DDL line to X71 (1).
2. Close off the X72 connection (DDL OUT) (2) with the DDL
terminator plug (left figure, see "Spare parts and
accessories" on page 84). This ensures a defined line
termination and the valve system complies with the IP 65
protection class.
)