Parameter Setting With E82Zbc Keypad - Lenze 8200 vector Instructions De Montage

Masquer les pouces Voir aussi pour 8200 vector:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7
Commissioning

Parameter setting with E82ZBC keypad

Parameter setting with E82ZBC keypad
,
Read the documentation for the keypad before starting work!
After every mains switching, or after connection of the keypad during operation, the 10 codes that
have been defined in code C0517 are immediately available.
By default, the user menu contains all codes required for commissioning a standard application with
linear V/f characteristic control:
Code
Designation
C0050
Output frequency
C0034
Range of setpoint
selection
C0007
Fixed configuration digital
inputs
C0010
Minimum output
frequency
C0011
Maximum output
frequency
C0012
Acceleration time main
setpoint
C0013
Deceleration time main
setpoint
C0015
V/f rated frequency
C0016
V
boost
min
C0002
Parameter set
management
)
Note!
Via C0002 "Parameter set transfer/establishing the delivery status", you can transfer
configurations from drive controller to drive controller by means of the keypad, or
re−establish the delivery status by loading the Lenze setting (e. g. if you've lost track
during parameterising).
136
Lenze setting
Display: output frequency without slip compensation
0
Standard I/O
Application I/O
0
E4
CW/CCW
Clockwise
rotation/counter−clo
ckwise rotation
0.00 Hz
50.00 Hz
5.00 s
5.00 s
50.00 Hz
device−dependent
Re−establish delivery status; transfer parameter sets by means
of the keypad; save, load, or copy own basic settings
l
X3/8: 0 ... 5 V / 0 ... 10 V / 0 ... 20 mA
X3/1U: 0 ... 5 V / 0 ... 10 V
X3/2U: 0 ... 5 V / 0 ... 10 V
E3
E2
DCB
JOG2/3
DC injection
Selection fixed setpoints
brake
EDK82EV113 DE/EN/FR 11.0
E1
JOG1/3

Publicité

Table des Matières
loading

Table des Matières