Wiring
}
Danger!
Faulty operation in case of earth faults possible
The correct functioning of the safety function is not ensured if an earth fault occurs.
Possible consequences:
A failure of the safety function can lead to death, severe injuries or damage to
ƒ
material.
Protective measures:
The electrical reference point for the coil of the safety relay K
the PE conductor system (EN 60204−1, paragraph 9.4.3)!
}
Danger!
Danger to life through improper installation
Improper installation of the safety engineering systems may cause an uncontrolled
starting action of the drives.
Possible consequences:
Death, severe injuries, or damage to material assets during an uncontrolled starting
ƒ
action of the drives.
Protective measures:
Shielded installation of all control cables connected to the FIF module is essential to
ƒ
reduce interference injection.
Apply the shield to a large surface of the EMC sheet.
ƒ
EDK82EV113 DE/EN/FR 11.0