4
Mechanical installation
Mounting in cold−plate design
Mounting in cold−plate design
For this mounting variant you require the controller type E82CV...
The following points are important for safe and reliable operation of the controller:
ƒ Good thermal connection to the cooler
– The contact surface between the collective cooler and the controller must be at least as
large as the cooling plate of the controller.
– Plane contact surface, max. deviation 0.05 mm.
– When attaching the collective cooler to the controller, make sure to use all specified screw
connections.
ƒ Observe the thermal resistance R
operation under rated conditions.
8200 vector
E82CV302K2C
E82CV402K2C
E82CV552K2C
E82CV752K2C
E82CV302K4C
E82CV402K4C
E82CV552K4C
E82CV752K4C
E82CV113K4C
Ambient conditions
ƒ The rated data and the derating factors at increased temperature also apply to the ambient
temperature of the drive controllers.
ƒ Temperature at the cooling plate of the drive controller: max. 75 °C.
108
given in the table. The values are valid for controller
th
Power to be dissipated by the heatsink
P
[W]
loss
100
127
167
213
97
120
153
200
273
l
Cooling path of heatsink − ambience
R
[K/W]
th
£ 0.23
£ 0.23
£ 0.13
£ 0.13
£ 0.23
£ 0.23
£ 0.23
£ 0.13
£ 0.13
EDK82EV113 DE/EN/FR 11.0