Lenze 8200 vector Instructions De Montage page 161

Masquer les pouces Voir aussi pour 8200 vector:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1)
Keypad
PC
Fault
15
Controller overload
OC5
during steady−state
a
operation
16
Motor overload
OC6
2
(I
a
50
Heatsink
OH
temperature > +85
a
°C
Heatsink
OH
temperature > +80
e
°C
Heatsink
OH
temperature > +80
e
°C
53
PTC monitoring
OH3
(TRIP)
a
(display when
C0119 = 1 or 4)
54
Controller
OH4
overtemperature
a
203
PTC monitoring
OH51
(display when
C0119 = 2 or 5)
EDK82EV113 DE/EN/FR 11.0
Troubleshooting and fault elimination
Cause
Frequent and too long overload
periods
Motor is thermally overloaded by
x t overload)
e.g.
l
impermissible continuous
current
l
frequent or too long
acceleration processes
Ambient temperature is too high
Heatsink is very dirty
Impermissible high currents or
frequent and too long
acceleration processes
Motor too hot due to
impermissible high currents or
frequent and too long
acceleration processes
No PTC connected
Controller is too hot inside
Motor too hot due to
impermissible high currents or
frequent and too long
acceleration processes
No PTC connected
l
Fault elimination
Fault messages
Remedy
Check drive dimensioning
l
Check drive dimensioning
l
Check setting of C0120
Allow controller to cool and provide
for better ventilation
Clean heatsink
l
Check drive dimensioning
l
Check load, replace
rough−running, defective
bearings, if necessary
Check drive dimensioning
Connect PTC or switch off monitoring
l
Reduce controller load
l
Improve cooling
l
Check fan in the controller
Check drive dimensioning
Connect PTC or switch off monitoring
8
161

Publicité

Table des Matières
loading

Table des Matières