Electrical installation
Connection of relay output K
Technical data
Terminal
Description
X3.1/K32
Safety relay K
X3.1/K31
1st disconnecting path
X3.1/33
X3.1/34
Terminal data
Cable type
Directly
coupled
to the
mains
Flexible With plastic sleeve
126
SR
Range
Coil voltage at +20 °C
SR
Coil resistance at +20 °C
Rated coil power
Max. switching voltage
Max. switching capacity, AC
Max. switching current (ohmic load)
Recommended minimum load
Max. operating frequency
Mechanical service life
Electrical service life
at AC 250 V
(ohmic load)
at DC 24 V
(ohmic load)
Wire end ferrule
l
Cable cross−section
Tightening torque Stripping length
2
2.5 mm
(AWG 14)
2
2.5 mm
(AWG 14)
Values
DC 24 V (20 ... 30 V)
823 W ±10 %
Approx. 700 mW
AC 250 V, DC 250 V (0.45 A)
1500 VA
AC 6 A (250 V), DC 6 A (50 V)
> 50 mW
6 switching operations per minute
7
10
switching cycles
5
10
switching cycles at 6 A
6
10
switching cycles at 1 A
7
10
switching cycles at 0.25 A
3
6 × 10
switching cycles at 6 A
6
10
switching cycles at 3 A
6
1.5 × 10
switching cycles at 1 A
7
10
switching cycles at 0.1 A
0.5 ... 0.6 Nm
5 mm
(4.4 ... 5.3 lb−in)
EDK82EV113 DE/EN/FR 11.0