Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9 Faults

Warning:
- Disconnect the power supply before carrying out work on the unit.
Work must only be carried out on the equipment by an electrical engineer with the
relevant training and qualifications.
Table 2, faults
Signaling
LED
on anti-static bar &
Ex Status Module
does not light up
LED
on anti-static bar &
Ex Status Module
Blinking Green
LED
on anti-static bar &
Ex Status Module
lights up Red
LED
on anti-static bar &
Ex Status Module
lights up Green
LED on anti-static bar
blinks Red & LED on
Ex Status Module
lights up Red
LED on anti-static bar
does not light up &
LED on Ex Status
Module lights up Red
PerformaxEasyExPerformaxEasyExSpeed_UM_9752153010_NL_D_ GB_F_V2_3
Problem
No High voltage on
the emitters
No High voltage on
the emitters
Anti-static bar
overload
No/poor ionization,
though High voltage
on the emitters
High voltage on the
emitters, no HV OK
signal
No High voltage on
the emitters, no HV
OK signal
Cause
No power supply
Wiring fault
No Remote on/off signal
Wiring fault
Anti-static bar
contimainated
Anti-static bar mounted
too close to conductive
machine parts
Anti-static bar
contimainated
Emitters are damaged
Anti-static bar wrongly
positioned
Emitters are covered
HV OK is overloaded
Wiring fault
Defective fuse in Ex
Status Module
Solution
Connect power supply
Detect error and repair,
see, see 5.8
Activate Remote on/off
Detect error and repair,
see, see 5.8.4
Clean Anti-static bar
Reposition Anti-static
bar
Clean Anti-static bar
Replace the anti-static
bar
Reposition the anti-
static bar, see 5.3
Remove cover
Change load HV OK
Detect error and repair,
see 5.8.4
Replace fuse.
Type: see chapter 4
70

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ion performax easy ex speed

Table des Matières