5.3 Anti-static bar mounting

Attention:
- Any conductive machine parts in the vicinity of the anti-static bar will negatively affect
its performance. For the best results the anti-static bar should be mounted in
accordance with Image 5.3.1.
- Mounting the anti-static bar:
• Place just before the location where the static electricity problem occurs.
• Place with an optimal distance from the material that should be neutralized:
o 100 - 300 mm (Performax Easy Ex)
o 50 - 300 mm (Performax Easy Ex (Speed))
• With the emitters in the direction of the material to be neutralized.
• Ensure that no material can come between the emitters and the material to be neutralized
• Attach the cable properly into the machine to prevent mechanical damage (suitable
conduit and clamps can be ordered separately).
Image 5.3.1: Optimal position Performax Easy Ex and Performax Easy Ex (Speed)