7. Functional check

The proper functioning is established by checking the material bonding.
Charging is affected by changes in the distance from charging bar to material as well as by
charging voltage and current changes.

8. Maintenance

Warning:
- When carrying out work on the equipment: de-energise the equipment.
- Keep the electrode clean.
- If fouled: Clean the points or blade with a hard non-metal brush.
- If heavily fouled: Clean the electrode with isopropyl alcohol.
Attention:
- Do not damage the points or blade.
- Make sure the electrode is entirely dry before you turn it on again.

9. Faults

Problem
No charging
Insufficient charging
Spark-over from electrode
Table 1: faults
Pinner_UM_9752092710_NL_D_GB_F_V2_1
Cause
High voltage power unit not
switched on
High voltage power unit
defective
Defective high voltage resistor
in electrode
HV cable interrupted
High voltage set too low
Charging current not set or set
too low
Distance from electrode to
material too large
Electrode fouled
High voltage set too high
Distance from electrode to
material too small
Remedy
Switch on the high voltage
power unit
Repair the high voltage power
unit
Replace high voltage resistor
Restore HV cable
Raise high voltage
Set (or raise) charging current
Mount the electrode closer to
the material
Clean the electrode
Reduce high voltage
Mount the electrode farther
away from the material