Electronically Controlled Fryer
The electronic series comes in a gas version and an electric version; it differs from the analogical
series only for its temperature regulator, which is an electronic card in place of a thermostat.
Place (fig. 4 -pag. 3)
It is advisable to install the appliance in a well- ventilated room or under an extractor hood. The
appliance may be installed as a single unit or together with others. In both cases, if it is installed
near a wall of inflammable material, a minimum distance of 150 mm from the side and back walls
must be observed (as in the figure on the left). In the event that it is not possible to observe this
distance, protective measures must be taken (e.g. use of sheets of refractory material) which ensure
that the temperature of the walls is within the established safety limits.
Installation
Installation operations, gas or voltage conversions other than the original provision, starting up the
installation or appliance, ventilation, letting out fumes, and maintenance must be done following the
manufacturer's instructions and observing the norms in force, by qualified personnel, in compliance
with the following provisions:
UNI CIG Norms 8723
Building regulations and local fire prevention provisions
Safety norms in force
Provisions of the Gas supplying company
The ECI provisions in force
FFVV Provisions
Fume evacuation
The appliances are divided into two types (see Tab. 1 - pag. 22):
Type "A" gas appliances
It is not necessary to connect this type of appliance directly to an evacuation pipe for combustion
products. The products of combustion, however, must be directed into suitable hoods or similar
devices, connected to a reliably efficient chimney, otherwise directly outside. In their absence the
use of an extractor fan is permitted connected directly to the external environment with a capacity
no lower than that stated in table 1. This value must be increased with the air exchange necessary
for the well being of the operators, in accordance with the norms in force. (approximately a total of
3
35 m
/h per kW of gas output installed).
PROVISIONS FOR INSTALLATION
Pag. 26