Gas type
Liquid Gases LPG
(G30-G31)
Natural Methane
Gas
(G20)
Town Gas
(G110)
Town Gas
(G120)
Liquid Gases LPG
(G30-G31)
Natural Methane
Gas
(G20)
Town Gas
(G110)
Town Gas
(G120)
WARNINGS
General
Read the instructions carefully before installation, use and maintenance of the appliance.
• Installation must be carried out by qualified personnel following the manufacturer's instructions
in the specific manual.
• The appliance must only be used by trained personnel and only for its intended use.
• In the event of breakdown or malfunctioning, switch off the appliance and contact after sales
assistance only at an authorised centre.
• Use only original spare parts; otherwise no liability is accepted by the manufacturer.
• The appliance must not be washed with high-pressure water sprays, neither must the openings or
air fumes on heat inlets/outlets be blocked.
ATTENTION! The manufacturer declines any liability for damage caused by wrong
installation, tampering, making unauthorised changes, improper use, poor maintenance,
installation of non-original spare parts, not observing local norms, incorrect use or not
observing the instructions in this booklet
For the installer
• The functioning of the appliance must be explained and shown to the user. After having ensured
that everything is clear, the instruction booklet must be handed over.
• The user must be informed that any building modification or restructuring that may in any way
modify the air supply necessary for combustion, makes it necessary to carry out another check of
the functionality of the appliance.
(Table 5) BURNER FEATURES (SE-DK)
Nominal
Reduced
Capacity
Capacity
[kW]
[kW]
FRYER BURNER ½ unit
18.00
-
18.00
-
17.00
-
18.00
-
FRYER BURNER 1 unit
18.00 x 2
-
18.00 x 2
-
17.00 x 2
-
18.00 x 2
-
Main Injector
By-Pass
Diameter
Diameter
[1/100 mm]
[1/100 mm]
130
190
500
500
130 x 2
190 x 2
500 x 2
500 x 2
Pag. 24
Pilot Injection
[N° ]
-
30
-
51
-
75
-
75
-
30 x 2
-
51 x 2
-
75 x 2
-
75 x 2
Air
Regulation"x"
[mm]
Open
Open
Open
Open
Open
Open
Open
Open