12.

MACHINE BLOCK ALARM MESSAGES

DISPLAY
UPPER PISTON MOTOR
GROUP ALARMORE
HEATER FILLING
ALARM
TURBINE ALARM
Ad allarme rilevato l'unità di con-
trollo alterna a display il mes-
saggio relativo alla bevanda in
corso con il messaggio di errore
associato a questa fuinzione. Ad
esempio:
74
CAUSA
EFFECT
During
the
The control unit
will halt whatever
group handling
cycle is on by
phase,
the
turning off both
upper
piston
the
exceeded maxi-
mum set time
actuator
those for drink
by 10 seconds
delivery;
before
reco-
operator will not
gnizing motor
pickup.
be able to make
selections on the
keyboard.
The heater fil-
The machine will
ling stage has
stop.
exceeded the
3 minute maxi-
mum time; the
probe level is
uncovered.
The
volume
The delivery will
counter
will
continue for up to
not send any
60 seconds or for
impulses to the
as long as any of
control unit for 5
the coffee based
seconds.
drink keys are
pressed.
SOLUTION
Open and close
the machine door.
movement
and
the
Open and close
the machine door.
The control unit
will repeat the
machine starting
up procedure.
EN
NOTE
If the alarm
r e a p p e a r s
after
the
second time
of taying, call
the
Service
Technician.
If
the alarm
r e a p p e a r s
after
the
second time
of taying, call
the
Service
Technician.
In case the
alarm persists,
the machine
can be used
as a manual
appliance.
• Press
the
selected key
to start the
dosing;
• Once
the
desired dose
has
been
d e l i v e r e d
in the cup,
press
the
same key to
halt the dose
being delive-
red.
Call
the
S e r v i c e
Technician.

Publicité