Setting The Welding Parameters - Leister GEOSTAR G5 Instructions D'utilisation

Masquer les pouces Voir aussi pour GEOSTAR G5:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Setting the welding parameters

CAUTION!
The welding wedge is set to 2 mm membranes in the factory settings.
The welding wedge (5) must be cooled down for adjustment purposes.
Danger of crushing when closing the clamping arm (4).
Switch o GEOSTAR with main switch (2) and disconnect from the mains.
Welding force and contacting system
A. Press the locking clamping lever (10) and swing clamping lever (7) upwards until the lock engages and use
your other hand to accomplish this by holding the automatic welding machine fi rmly by the handle (11) . Un-
lock welding force safety bolts (9) by pulling and rotating 90°. Set the clamping arm (4) to the maximum
opening using the welding force adjustment ring (8).
11
10
B. While unclamped, release the upper contacting system locking screw (21) and the lower contacting
system locking screw (22). Screw the upper contacting system adjusting screw (19) and the lower
contacting system adjusting screw (20) with a socket wrench (wrench size 4 mm) a su cient distance away
from the welding wedge (5).
8
7
19
5
9
21
22
20
4
51