Welding wedge position factory setting
H. If the upper and lower contacting sys-
tems (14/15) are set, then the rest of
the membranes are allowed to run over
the welding wedge (5) and the welding
wedge (5) is monitored to see whether
it shifts further in horizontal position to
the upper and lower drive/pressure
rollers (16/17). If this is the case, then
the contact pressure of the upper and
lower contacting system (14/15) is too
high and must be adjusted once again.
Switch off the main switch (2) and
disconnect GEOSTAR from the mains.
Afterwards, the upper and lower cont-
acting system setting screws (19/20)
must be locked with the upper and
lower contacting system locking
screws (21/22).
I. Press clamping lever locking device
(10) and swing clamping lever (7) up-
wards until the lock engages and use
your other hand to accomplish this by
holding the automatic welding machine
fi rmly by the handle (11) . Remove test
strips.