Leister GEOSTAR G5 Instructions D'utilisation page 52

Masquer les pouces Voir aussi pour GEOSTAR G5:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Setting the welding parameters
C. Insert test strips (lower and upper membranes) of the material to be welded between the upper and lower
drive/pressure rollers (16/17) and between the upper and lower contacting systems (14/15) and welding
wedge (5). Press the locking clamping lever (10) and close the clamping arm (4) using the clamping lever
(7) while at the same time using the other hand to accomplish this by holding the automatic welding machine
fi rmly by the handle (11). Rotate the welding force adjustment ring (8) until the pressure rollers touch lightly
against the material to be welded.
11
D. Connect the GEOSTAR to the mains and switch on the main switch (2). Press the locking clamping lever
(10) and swing clamping lever (7)upwards until the locking clamping lever (10) engages and use your other
hand to accomplish this by holding the automatic welding machine fi rmly by the handle (11) . Rotate the
welding force adjustment ring (8) until the welding force matches the desired value with the clamping arm
(4) clamped and test strips inserted. Afterwards, one has the clamped membranes glide for approx. 2 sec. at
the lowest speed over the welding wedge (5). The welding wedge (5) is thus moved into its fi nal position.
CAUTION!
Mechanical damage could occur if the maximum welding force of 1500 N is exceeded.
Moving parts may not be touched. The danger exists of inadvertently becoming
caught and being pulled in.
52
14
15
11
2
7
8
10
5
16
17
10
5
7
8
4
4

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Geostar g7

Table des Matières