6.3 Switching on the blower

• Once you have prepared the working area and the blower in accordance with the description, connect the blower
to the mains voltage.
• Switch the blower on via the toggle switches (5).
• Before adjusting the temperature on the connected hot air device, make sure that there is enough air escaping.

6.4 Switching off the blower

• Switch the blower off via the toggle switches (5). When the toggle switches (5) have been switched off, the
outlet below will also be switched off.
• When both toggle switches (5) have been switched off, the blower turns itself off automatically after approx.
5 minutes (cool-down function).
• After the blower has been shut off, disconnect the power cord (1) from the mains.

6.5 Maintenance

• Do not use aggressive substances to clean the housing (3).
• Check the power cord (1) and plug before every use. These may not be damaged.
• Check the blower filter mats at least every 2 months. In case of extremely dirty ambient conditions, the filter must
be checked sooner.
First disconnect the power cord (1) from the power supply and then open the housing cover (6 screws).
For the blower below, loosen and remove the two cover screws. The filter mats are located below.