[B000005] The doors can be mounted to reinforced concrete walls, those
made of bricks, or steel framework. A room intended to mount the doors should
be finished completely (plastered walls, finished floor), walls must not have any
faults in quality of work. The room should be dry and free of chemicals being
harmful for coating paints.
Both side walls, and frontal wall and door assembly opening lintel must be verti-
cal and perpendicular to the floor, and must be finished.
it is prohibited to mount the door in a room in which fin-
ishing works are still to be done (plastering, gypsum fin-
ishing, grinding, painting, etc.).
Floor in bottom sealing area must be levelled and constructed in such a way
as to ensure free water drain. Appropriate ventilation (drying) of garage must
be ensured.
installing of electrical drive unit to the door by profes-
sional installer or competent person is to be done ac-
cording to the Assembly and Operating instruction of the
drive unit.
[B000092] The area to install the door should be free from any pipes, cables, etc.
• [C000184] it is prohibited to open the door leaf without
guides mounted.
• [C000230] it is prohibited to carry the door with its ex-
ternal plating looking downwards.
[B000089] Safety Conditions
• The methods of electrical installation as well as its protection against electric
shock are described by the norms and regulations in force.
• The power supply circuit of the drive should be equipped with power cut,
residual-current device and overload circuit protection.
• The door power supply should be done as a separate power circuit.
• Grounding of the drive unit is obligatory and should be done in the first place.
• Only cables supplied together with the drive by the manufacturer should be
used to assemble the drive unit.
• Electrical installation should be done according to the acting regulations of
a particular country.
• All electrical works must be performed by certified installer only.
[D000368] 7. ASSEmBLy iNStRUCtiON
The correct operation of the door is closely connected with its proper assem-
bling. The manufacturer recommends the authorized assembly companies. Only
the proper assembly and maintenance according to the Instruction and provid-
ed by the competent company or person may guarantee safe and designated
operation of the door.
[D000369] 7.1. ASSEmBLy PROCEDURE
Fig.0.2.
Prior to installation works, check the dimensions (width and height)
of the assembly opening.
Fig.0.3.
If necessary, finish the opening so as to ensure that door frame fits
in it with clearance allowing to adjust the door horizontally and
vertically in the opening plane.
Fig.1-3.
Position the door vertically and horizontally during the first stage
of installation. Check whether door leaf adheres to the frame
along the whole perimeter. If necessary, a deviation in the door
setting of up to 2 [mm] per 1 [m] is acceptable, provided that
door leaf works with the frame properly. In case if there is too
much friction between door leaf and frame, check if the guides are
positioned perpendicular to the door lintel (or check diagonals of
the guides). If these conditions are satisfied, it is allowed to bend
the arms so as to correct the door operation.
Fig.4-15.
Carefully perform further installation operations shown on Figures.
Fig.8-9.
Check the diagonals of the horizontal guides. Mount the guides to
the ceiling with fastening brackets.
Fig.4,11,12. Mount the door using mounting anchors. The number of anchors
is adjusted to the number of door mounting plates.
Fig.13.1.
After mounting, cut the protruding parts of the brackets, blunt its
edges and protect the edges with paint.
Fig.13.3.
Mounting of horizontal guides to the ceiling with two sets of fasten-
ing brackets.
Fig.16.
Mounting of the door with brush sealing. Dismantle the door
threshold, and then mount the door using mounting anchors. The
door is mounted directly to the ground.
Fig. I.
When the door installation is complete, check, whether the door
operates according to the Assembly and Operating Instruction. If
necessary, make corresponding adjustments. Check the correct
Technical documentation
IIiO/BGU/12/2012/ID-93551
Assembly and Operating Instructions – Up and over garage door
tension of springs, and, if necessary, adjust it (any adjustments of
the door could only by made when the door is in its full open posi-
tion and secured from uncontrolled closing). To do this:
• open the door by lifting its leaf to half-open position (approx.
45° angle),
• if the leaf is visibly falling, increase the spring tension by regu-
lating the springs according to fig. I.II,
• if the leaf is visibly lifting, decrease the spring tension by regu-
lating the springs according to fig. I.II.
[D000328] 7.2. FAULtS DURiNg DOOR iNStALLAtiON
There is a risk that some faults may occur during door installation, which could
be easily avoided, provided that:
• door guides had diagonals and were parallel to each other,
• door leaf had diagonal in its closed position,
• side tolerances between the door frame and leaf were equal on both sides,
• all mounting elements are assembled properly.
Non-observation of the above basic recommendations may lead to troubles in
door operation, door damage or, as a result, provide to the loss of the warranty.
[A000007] 8. ADDitiONAL REQUiREmENtS
After the installation is completed, it must be checked that the door is fitted with
CE data plate according to the standard. If the plate is missing, fit the door with
the data plate. After verifying the correct operation of the door, the Assembly
and Operating Instruction and door book, if required, should be handed over
to the Owner.
[A000008] 9. ENviRONmENtAL PROtECtiON
Packaging
Elements of packaging (cardboard, plastics, etc.) are classified as waste suit-
able for recycling. Follow local legislation for specific material before throwing
it away.
Scrapping of equipment
The product consists of many different materials. Most of the materials used are
suitable for recycling. Sort it before disposal, and then deliver to refuse collec-
tion and disposal area for recycling.
Follow local legislation for specific material before
scrapping.
[A000009] Remember! Recycling of packaging materials
saves natural resources and reduces the amount of waste
material.
[D000329] 10. DiSASSEmBLy OF tHE DOOR
1. Close and bolt the door.
2. Remove brackets and guide.
3. Pull out the door from the opening. Always keep it with the plating upwards.
4. Protect the leaf against its uncontrolled opening before transport.
[D000330] 11. OPERAtiNg REmARKS
The basic conditions for the proper door usage that guarantee its durable and
trouble-free operation:
• provide free water drain in the area of bottom sealing,
• protect the door against harmful agents (including corrosive agents, like ac-
ids, alkali, salts), which may damage the paint coating and metal,
• protect the door against plaster, paints and solvents which may cause stains,
during finishing works,
• the springs counterbalancing the door leaf are designed for 10 000 cycles,
as standard. When the door completes the designated amount of cycles, the
springs must be definitely replaced,
• doors with electric drive must be opened according to the Instruction pro-
vided with the electric equipment,
• check the proper door installation if the excessive resistance during opening
the door is observed. If necessary, carry out the adjustments as stated in the

assembly instruction,

• it is prohibited to open the door equipped with the wicket door, unless the
wicket door is closed with the key.
[D000331] the range of environmental conditions, for which the
door has been designed
• Resistance to water penetration
• Resistance to wind load
• Air permeability
[A000029] 12. OPERAtiNg AND mAiNtENANCE iNStRUCtiON
The Assembly and Operating Instruction is a documentation intended for the
door owner. Please read carefully this instruction and follow its recommenda-
EN
- class 0
- class 4
- class 0
3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Elegant