Safety Instructions

To reduce the risk of ignition of a flammable or explosive atmosphere, strictly
adhere to the following Caution and Warning statements:
Increased hydrogen concentrations within the measuring range of the Dräger
Sensor XXS H
HC may result in false alarms due to the additive effect on the
2
Dräger sensors XXS H
S, and XXS CO, XXS H
2
well as due to the negative effect on the Dräger Sensor XXS O
Only use power packs ABT 0100 (83 22 237), HBT 0000 (83 18 704) or
HBT 0100 (83 22 244). See marking on power pack for approved batteries and
related temperature class.
Do not change batteries in hazardous locations.
To reduce the danger of explosion, do not mix new batteries with old batteries
and do not mix batteries made by different manufacturers.
Always disconnect the instrument from the power pack before carrying out any
maintenance operations.
Substitution of components may impair intrinsic safety.
Not tested in an oxygen-enriched atmosphere (>21 % O
WARNING
S (LC) and XXS CO (LC) as
2
.
2
WARNING
WARNING
WARNING
WARNING
WARNING
CAUTION
).
2
What is What
1
2
2
3
8
+H
2
X-am 5600
7
6
4
0
5
1
Gas entry
2
Alarm LED
3
Horn
4
[ OK ] key
5
Power pack
6
[ + ] key
7
Display
Special symbols:
Fault message
Warning
Display peak value
Display TWA
Show STEL
Bump test mode
Fresh air calibration
CO
2
Vol%
9
ch
4
%UEG
10
O
2
Vol%
CO
ppm
H
S
2
ppm
11
NH
3
ppm
12
13
14
15
9
IR interface
10
Fastening clip
11
Model plate
12
Charging contacts
13
Measured gas display
14
Measuring value display
15
Special symbols
1-button adjustment
Single-gas adjustment
Password necessary
Battery 100 % full
Battery 2/3 full
Battery 1/3 full
Battery empty
15