6.2 Attaching the sling to the lift

WARNING!
Risk of Injury
Usage of wrong or damaged slings can cause the
patient to fall or cause injury to assistants.
– Use an Invacare approved sling that is
recommended by the individual's doctor, nurse
or medical assistant for the comfort and safety
of the individual being lifted.
– Invacare slings and patient lift accessories are
specifically designed to be used in conjunction
with Invacare patient lifts.
– After each laundering (in accordance with
instructions on the sling), inspect sling(s) for
wear, tear, and loose stitching.
– Bleached, torn, cut, frayed, or damaged slings
are unsafe and could result in injury. Discard
immediately.
– DO NOT alter slings.
WARNING!
Risk of Injury
Improperly attached or adjusted slings can cause
the patient to fall or cause injury to assistants.
– Be sure to check the sling attachments each
time the sling is removed and replaced, to
ensure that it is properly attached before the
patient is removed from a stationary object
(bed, chair or commode).
– DO NOT use any kind of plastic back
incontinence pad or seating cushion between
patient and sling material that may cause the
patient to slide out of the sling during transfer.
– Position the patient in the sling as directed by
the instructions provided with the sling.
– Adjustments for patient safety and comfort
should be made before moving the patient.
The loops of the sling may be equipped with color coded
straps providing different length, to place the patient in
various positions. Match the corresponding colors on each
side of the sling for an even lift of the patient.
Invacare® Stand Assist sling
WARNING!
Risk of Injury
– Using a Stand Assist sling the patient must
be able to support the majority of their own
weight.
– Make sure the bottom edge of the Stand Assist
sling is placed on the lower back of the patient
and the patient`s arms are outside of the sling.
– The belt must be snug to prevent the patient
from sliding out of the sling.
1654371-A
C
A
1. Place the loops A of the sling B over the hooks C on
the lifting arm.
Invacare® Transfer Stand Assist sling
WARNING!
Risk of Injury
– Make sure the bottom edge of the Transfer
Stand Assist sling is placed at the base of the
patient`s spine and the patient`s arms are
outside of the sling.
– Do not raise the patient to a full standing
position using the Transfer Stand Assist sling.
C
A
E
D
1. Place the upper loops A of the sling B over the hooks
C on the lifting arm.
2. Place the lower loops D of the sling B over the hooks
E on the boom.
Patient Transfer
B
B
19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Isa compactIsa standardIsa plusIsa xplus

Table des Matières