5. Device overview

5.1 Signal indicator
LED
Power - green
Supply voltage
LED
Actuate - yellow
Sensor actuated
LED
Fault - red
Sensor circuit interrupted
LED
AUX. Relay - yellow
Auxiliary output switched

5.2 Connection terminals

A1 A2
Supply voltage 230 V 50/60 Hz (SK 41-32)
A1 A2
Supply voltage 115 V 50/60 Hz (SK 41-82)
B1 B2
Supply voltage 24 V AC/DC
X1 X2
Sensor connection
13 14
Safety-relay switching contact 1
23 24
Safety-relay switching contact 2
31 32
Auxiliary relay switching contact
Z1 Z2
Connection of manual reset
S11 S12
Coding inputs reset

5.3 Versions

Version
Housing
Supply voltage
Auxiliary relay
(switching contact
31 32)
SK 41-32
SK 41-32 RLU
Housing, 22.5 mm wide, made of polyamide for 35 mm DIN rail mounting
230 V 50/60 H�
230 V 50/60 H�
and 24 V AC/DC
and 24 V AC/DC
In the event of
Switches as long
an actuation or
as the sensor is
an error of the
actuated or a
sensor, switches
sensor error is
after 1 sec. for
signalled.
3 sec.
Z1 Z2 S11 S12
B1 B2 X1 X2
Power
Actuate
Fault
Aux. Relay
SK 41
A1 A2 31 32
13 14 23 24
SK 41-82
acc. to EN 60715.
115 V 50/60 H�
and 24 V AC/DC
In the event of
an actuation or
an error of the
sensor, switches
after 1 sec. for
3 sec.
SK 41-82 RLU
115 V 50/60 H�
and 24 V AC/DC
Switches as long
as the sensor is
actuated or a
sensor error is
signalled.
15