Device Overview; Versions; Signal Indicators; Connection Terminals - ASO Safety Solutions ELMON 41-322 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Safety Relay

6. Device overview

6.1 Versions

Version
ELMON relay 41-322
ELMON relay 41-822

6.2 Signal indicators

LED Power (green)
Operati ng state (on)
Fault alarm (pulse)
LED CH 1 (red)
Sensor operated (on)
Sensor power circuit interrupted (fast fl ashing)
Fault self-retaining (slow fl ashing)
LED AUX 1 (yellow)
Signal output switched
If there is no fault alarm, then the operati ng state is shown via the Power LED (on). When a fault alarm is issued,
the number of pulses output indicates the fault:
Pulse
Fault alarm
1
Voltage supply outside the valid value range
2
Fault when testi ng signal input
3
Output control relay faulty
4
Data transmission between micro-controllers faulty
7
Error change confi gurati on reset or signaling relay
6.3 Connecti on terminals
ELMON relay 41-322: Supply voltage 230 V 50/60 Hz
A1 A2
ELMON relay 41-822: Supply voltage 120 V 50/60 Hz
B1 B2 Supply voltage 24 V AC/DC
X1 X2 Connecti on sensor
X3 X4 Internal terminati ng resistor
13 14 Switching contact safety relay 1
23 24 Switching contact safety relay 2
31 32 Switching contact signal relay
Z1 Z2 Connecti on manual reset /re-start (key NO; opti onal)
18
Supply voltage
230 V 50/60Hz and 24 V AC/DC
120 V 50/60 Hz and 24V AC/DC
ELMON relay
41-322/41-822

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Elmon 41-822

Table des Matières