5. System components fitted to the gate

1
1 2
2
Example of use
The actual arrange�ent o� the individual co�po-
nents depends on the design o� the gate in question
and the conditions at the installation site.

6. Device overview

6.1 Signal indicators

LED POWER green
LED FAULT OPEN red
LED FAULT CLOSE red
I� no error is present, then LED Power shows the �unction control (briefl�� off). During the output o� an error
�essage, the nu�ber o� output pulses indicates the error:
Pulse
1
2
3
6.2 Connection terminals
Pin 1, 2
Stationar�� coil core
Pin 3
Suppl�� voltage +24 V DC
Pin 4
GND
Pin 5, 6
Output Stop closing �ove�ent
Pin 7, 8
Output Stop opening �ove�ent
Pin 9
Test input
Pin 10
No assign�ent
1
�elay
2
1 Control device ISK 70-755
2 Stationar�� coil core
3 Travelling coil core
4 Steel cable acting as trans�ission �ediu�
Functional test (off briefl��)
Error �essage (pulse output)
Fault, opening �ove�ent - travelling edge(s)
Fault, closing �ove�ent - travelling edge(s)
Error �essage
Voltage suppl�� outside o� the valid value range
ISK trans�ission error
Data trans�ission with �icrocontroller �ault��
4
3
1
LED
2
Power
3
4
5
LED
6
Fault Opening
7
8
LED
9
10
Fault Closing

Publicité