This symbol indicates the presence of devices sensitive to Electro-static Discharge
(ESD) and indicates that care must be taken to prevent damage with the equipment.
This symbol, when noted on a product, indicates the instrument is connected to
alternate current.
Electrical equipment marked with this symbol may not be disposed of in European
domestic or public disposal systems. Return old or end-of-life equipment to the
manufacturer for disposal at no charge to the user.
Products marked with this symbol indicates that the product contains toxic or
hazardous substances or elements. The number inside the symbol indicates the
environmental protection use period in years.
3.5 Overview
The ORBISPHERE 3100 instrument is a self-contained portable analyzer, configured to make
oxygen concentration measurements in gaseous or liquid samples. Up to 5,760 measurement values
can be stored in memory and downloaded to a personal computer for further analysis.
The analyzer is available in 3 different versions (for 4mm, 6mm and 1/4 inch connections).
Section 4 Installation
This instrument is for indoor use only.
Carefully remove the analyzer and its accessories from the box and packing material, referring to the
packing list included to confirm that everything has been delivered. Please visually inspect the
analyzer for shipping damage. If anything is missing or damaged, contact the manufacturer or your
dealer immediately.
A thin protective film has been placed over the screen to protect it from damage during
transportation. For a clear view of the screen, this film must be peeled off before using the analyzer.
A secondary more robust protective film has been factory installed over the screen to protect it from
damage and moisture ingress. Under no circumstances should this protection be removed. If it
becomes damaged in any way, please contact your local Hach representative.
4.1 Installation startup checklist
1. Reconnect the battery pack in order to supply power to the instrument as described in
battery power
on page 8.
2. Switch the machine ON using the ON/OFF switch (No. 2 in
need charging, connect the instrument to an external power source as described in
power
on page 10.
3. Next, familiarize yourself with using the instrument by reading the next section in this manual
entitled
User interface
4. Set the date and time of the instrument's internal clock, as described in
on page 16.
5. Install the 3100 PC software on your PC as described in
6. Set up the user configuration table using the PC software as described in
on page 11.
N O T I C E
N O T I C E
on page 12.
Figure 1
on page 9). If the batteries
Basic settings
PC software installation
Create new user table
Reconnect
External
on page 11.
English 7