Kollmorgen AKM 2G Manuel D'installation page 201

Masquer les pouces Voir aussi pour AKM 2G:
Table des Matières

Publicité

7.5.3.1 AKM2G-53 Derates for Different Options
De-rates are referenced to the Max Continuous Torque ΔT wdg. = 100°C
Options - No Brake
Resolver
Resolver / Seal
SFD
SFD / Seal
DSL
DSL / Seal
De-rates are referenced to the Max Continuous Torque ΔT wdg. = 100°C
Options - Brake
Resolver
Resolver / Seal
SFD
SFD / Seal
DSL
DSL / Seal
0
1000
100.0%
92.2%
99.4%
90.8%
100.0%
92.2%
99.4%
90.8%
100.0%
92.2%
99.4%
90.8%
0
1000
2000
99.7%
91.8%
82.2%
99.1%
90.5%
79.7%
99.7%
91.8%
81.7%
99.1%
90.5%
78.7%
99.7%
91.8%
81.7%
99.1%
90.5%
78.7%
Kollmorgen | kdn.kollmorgen.com | August 2018
AKM2G Instructions | 7   Technical Data
Speed: RPM
2000
3000
4000
82.5%
73.0%
63.7%
80.1%
69.2%
58.3%
81.7%
70.6%
59.5%
78.7%
65.8%
52.4%
81.7%
70.6%
59.5%
78.7%
65.8%
52.4%
Speed: RPM
3000
4000
72.6%
63.2%
68.8%
57.8%
70.6%
59.5%
65.8%
52.4%
70.6%
59.5%
65.8%
52.4%
5000
5100
54.7%
53.8%
47.6%
46.5%
48.6%
47.5%
38.4%
37.0%
48.6%
47.5%
38.4%
37.0%
5000
5100
54.2%
53.2%
45.1%
43.9%
48.6%
47.5%
38.4%
37.0%
48.6%
47.5%
38.4%
37.0%