Télécharger Imprimer la page

DeWalt DPC6MRC-QS Manuel D'instructions Et D'utilisation page 10

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
ENGLISH
ELECTRICAL CONNECTION
Do not abuse the cord. Never use the cord for carrying,
pulling or unplugging the power tool. Keep cord away
from heat, oil, sharp edges or moving parts.
Damaged or entangled cords increase the risk of electric
shock.
Single-phase compressors are supplied with an electrical
cable and a two-pole & earth plug. The compressor must be
connected to a grounded power socket.
IMPORTANT: Never use the ground socket instead of the
neutral wire. The ground connection must be made to
meet safety standards (EN 60204). The plug of the power
cable must not be used as a switch, but must be fitted in
a power socket controlled by a suitable differential switch
(thermalbreaker).
m DANGER: RISK OF ELECTRICAL SHOCK. IMPROPER
GROUNDING CAN RESULT IN ELECTRICAL SHOCK.
Do not modify the plug provided. If it does not fit the available
outlet, a correct outlet should be installed by a qualified
electrician.
Repairs to the cord set or plug MUST be made by a qualified
electrician.
PREPARATION FOR USE
PRE-START CHECKLIST
1. Ensure the On/Off switch (6) is in the OFF position.
2. Plug the power cord into the correct branch circuit
receptacle. See Electrical Connection (above).
3. Ensure air tank is drained, see Draining Air Tank under
Maintenance.
4. Ensure the drain valve (2) is closed.
5. Ensure safety valve (14) is functioning properly, see
Checking Safety Valve under Maintenance.
6. Check pump oil level, see Compressor Pump Oil under
Maintenance. (DPC16PS Only)
m CAUTION: Do not operate without oil or with inadequate
oil. D
WALT is not responsible for compressor failure
e
caused by inadequate oil.
7. Turn regulator knob (4) counterclockwise until fully closed.
Ensure regulated pressure gauge reads 0 bar (0 psi).
8. Attach hose and accessories.
m Warning: Risk of unsafe operation. Firmly grasp hose in
hand when installing or disconnecting to prevent hose
whip.
9. Ensure all covers and labels are in place, legible (for labels)
and securely mounted. Do not use compressor until all
items have been verified.
m Warning: Risk of bursting. Too much air pressure causes
a hazardous risk of bursting. Check the manufacturer's
maximum pressure rating for air tools and accessories.
The regulator outlet pressure must never exceed the
maximum pressure rating.
10
All manuals and user guides at all-guides.com
INITIAL SET-UP
m Warning:Do not operate this unit until you read and
BREAK-IN PROCEDURE
m CAUTION: Risk of property damage. Serious damage may
result if the following break-in instructions are not closely
followed.
This procedure is required before the air compressor is put
into service for the first time and when the check valve or a
compressor pump/motor has been replaced.
1. Ensure the On/Off switch (6) is in the OFF position.
NOTE: If hose is not connected to Quick Connect body, pull
coupler back until it clicks to prevent air from escaping
through the quick connect.
2. Plug the power cord into the correct branch circuit
3. Open the drain valve (counter-clockwise) fully to permit air
4. Move the On/Off switch to the ON position. The compressor
5. Run the compressor for 20 minutes.
6. After 20 minutes, close the drain valve by turning
7. Compressed air will be available until it is used or bled off.
STARTING
Check that the mains power matches that indicated on the
electrical data-plate - the permissible tolerance range is
+/-5%. Turn or press into position "0". Fit the plug in the
power socket and start the compressor, turning the pressure
switch knob into position "I".
The compressor is fully automatic, and is controlled by
the pressure switch which stops it when tank pressure
reaches maximum value and restarts it when it falls to
minimum value. The pressure difference between maximum
and minimum values is usually about 2 bar (29 psi). E.g.:
the compressor stops when it reaches 8 bar (116 psi) -
maximum operating pressure) and restarts automatically
when the pressure inside the tank drops to 6 bar (87 psi).
After connecting the compressor to the power line, load it to
maximum pressure and check exactly how the machine is
operating.
NOTE: The head/cylinder/delivery tube unit can reach high
temperatures. Take care when working near these parts, and
do not touch them to avoid possible burns.
IMPORTANT
The electro-compressors must be connected to a power
socket protected by a suitable differential switch (thermal-
breaker). The motor is equipped with an automatic
understand this instruction manual for safety, operation
and maintenance instructions.
receptacle. See Voltage and Circuit Protection under
Installation.
to escape and prevent air pressure build up in the air tank
during the break-in period.
will start.
clockwise. The tank will fill to cut-out pressure and the
motor will stop.

Publicité

loading