Electrical Connection - Enodis Cleveland MKDL-40-T Manuel De L'opérateur

Marmites malaxeuses à vapeur directe
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ELECTRICAL CONNECTION

Fused disconnect
A separate fused disconnect (supplied by installer) is required for this equipment. Follow chart
below to properly size disconnect.
Model
MKDL-40-T to MKDL-150-T
TMKDL-40-T to TMKDL-150-T
ELECTRICAL
NOTE: Ensure the electrical supply matches the unit's requirements as stated on the rating label.
This unit is built to comply with CE standards. Many local codes exist, and it is the responsibility
of the owner and installer to comply with these codes.
NOTE: Maximum voltage for LVD is 440 volts for CE marked appliances.
ELECTRICAL SERVICE CONNECTIONS
The electric supply must match the power requirements specified on the kettle's rating plate. The
copper wiring must be adequate to carry the required current at the rated voltage. Refer to the
specification sheet for electrical specifications.
1. Ensure main power is turned off before connecting wires.
2. Remove the screws at the rear of the center console cover, and remove the cover. A wiring
diagram is affixed to the underside of the console cover.
3. Feed permanent copper wiring 18" through the cut-out in the bottom of the console. Connect
wiring in junction box in the bottom of the console.
4. Turn main power back on.
5. Check for correct rotation of electric motor (access by removing top front cover on center
console). If rotation is incorrect, disconnect main power and reverse any two of the three live
lines.
6. Replace the console cover and secure it with screws.
3
RED
YELLOW
BLACK
The kettle is wired for 3-phase operation at the factory.
Supply
Amps
voltage
200-208
15
220-240
14
380-415
9
PE
Green/
L1 L2 L3
Yellow
Phase
Wire Size mm2
3
3.3
3
3.3
3
2.1
1
RED
YELLOW
BLACK
L1
L2
Fused
Disconnect
AMPS
20
20
15
PE
Green/
Yellow

Publicité

Table des Matières
loading

Produits Connexes pour Enodis Cleveland MKDL-40-T

Table des Matières