CAP.2
SPECIFICHE TECNICHE
PORTATA:..........................................7000 Kg (68647 N)
Tempo di salita con motore trifase .....................
Tempo di discesa ...............................................
Peso totale del sollevatore..........................circa 1680 Kg
Rumorosità ..................................................<70dB(A)/1m
Temperatura di funzionamento :.................-10°C / +50°C
Pressione di lavoro......................................210 bar
Ambiente di lavoro: locale chiuso.
Fig.7 Dimensioni ed ingombri
MOTORE ELETTRICO:
Potenza del motore elettrico
Tensione
Frequenza
Assorbimento
N° poli
Velocità
Forma costruttiva
Classe di isolamento
Tipo
Il collegamento del motore deve essere eseguito riferendosi agli schemi
elettrici allegati.
Il senso di rotazione del motore deve coincidere con quello indicato dal-
la freccia sulla pompa; in caso contrario modificare i collegamenti elet-
trici (Vedere Cap.4 INSTALLAZIONE- Allacciamento impianto elettrico).
POMPA della centralina idraulica:
Tipo
Modello
Cilindrata
Taratura valvola di massima
CHAPTER. 2 TECHNICAL SPECIFICATIONS
CAPACITY:.........................................7000 Kg (68647 N)
44 sec
Rise time with three-phase motor..........................44 sec.
42 sec
Descent time .....................................................
Total lift weight...........................................about 1680 Kg
Noise ...........................................................<70dB(A)/1m
Operating temperature: ................................-10°C/+50°C
Working pressure ........................................210 bar
Work environment: closed room.
ELECTRIC MOTOR:
Trifase
3 kw
Electric motor power rating
230-400V trif.+/-5%
Voltage
50 HZ
Frequency
230V:15A
Absorption
400V:8,7A
4
N° of poles
1400
Speed
B14
Construction size
IP54
Insulation class
90L4
Type
The motor must be connected with reference to the attached
wiring diagrams.
The motor rotation direction must be the same as shown by the arrow on
the pump; if not, modify the electrical connections (see Ch.4,
INSTALLATION-electric plant connection)
HYDRAULIC UNIT PUMP
MOTORE
Trifase
20
Type
10A7,4X348N
Model
7.4 cm
/g
Size
3
210 bar
Relief valve set-up
42 sec.
Fig.7
Dimensions and overall clearances
Three-phase
3 KW
230-400V 3ph.+/- 5%
50 Hz
230V:15A
400V: 8,7A
4
1400 RPM
B14
IP54
90L4
MOTOR
3-ph.
20
10A7,4X348N
7.4 cm
/g
3
210 bar