Télécharger Imprimer la page

Ingersoll Rand EZTT080300 Manuel Utilisateur Et Maintenance page 6

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
Installed Safety Cable
(Dwg. MHP1681)
2.
Interlock the two thimbles (21) and route wire rope through
thimbles. Determine appropriate length of wire rope and, using side
cutters, cut to length.
3.
Install first clamp (22) assembly one clamp width from dead end of
wire rope. Snug the nuts, but do not torque.
4.
Install second clamp (22) at thimble end. Snug nuts but do not
torque.
5.
Remove any slack wire rope between thimble and clamp, and
between the two clamps. Torque nuts to clamp wire rope.
6.
Repeat steps 3 through 5 for the other end of wire rope.
(Dwg. MHP2131)
5
Safety Cable Parts List
Item
Description
No.
of Parts
21
Thimble
22
Clamp Assembly
23
Wire Rope
Attaching the Tool Holder
Refer to Dwg. MHP1697 shown on page 5.
Attach tool holder to lower flange of tool extension using four capscrews,
washers, nuts and two clamping plates. To position tool holder, loosen
capscrews and rotate until desired position is achieved. Retighten
capscrews. Torque fasteners to 30 Nm (22 ft lbs).
Install tool in tool holder and tighten capscrews to clamp into position.
Tool Holder Components
360° Swivel Type
(Dwg. MHP1697)
Attaching a Spring Balancer
Connect spring balancer to internal column.
On 2 to 12 kg (4.5 to 26.5 lb) capacity units connect spring balancer to
hanger plate with shackle and attach hanger plate to internal column with
two capscrews, nuts and washers.
On 10 to 20 kg (22 to 44 lb) capacity units connect spring balancer
directly to internal column using two capscrews, nuts and lockwashers.
Attach spring balancer wire rope to external column. Refer to the spring
balancer manual for additional installation instructions.
Attaching Air Cylinder
Position cylinder parallel to column and align cylinder end clevis with
hole in internal column cross bar. Use hole nearest column as shown on
Dwg. MHP1680 on page 4. Install pin (16) and secure in position.
Attach cylinder rod end clevis to external column. Install pin and secure in
position.
Qty.
Part
Total
No.
2
10212
4
10235
As Req'd.
10099
MHD56172 - Edition 2

Publicité

loading

Ce manuel est également adapté pour: