Integrated Dryer; Environmental Limits - Ingersoll Rand R30 Information De Produit

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

93014.15.06
Substance
Langelier Index (LI)
Ammonia [NH3 ], ppm
Ammonium [NH4-1], ppm
Chlorides [Cl-], ppm
Copper [Cu], ppm
Dissolved Oxygen (DO) [O2], ppm
Iron + Manganese [Fe + Mn], ppm
Nitrate [NO3 -], ppm
Oil & Grease, ppm
Silicon Dioxide (silica) [SiO2], ppm
Sulfates [SO4-2], ppm

Integrated Dryer

Do not connect condensate drains common to other pressurized drain
lines in a closed circuit. Make sure the outfl ow from the condensate drains
is unimpeded. Connect the condensate piping in such a way to ensure that
sound levels are kept to a minimum during drainage.
Ensure that all condensate is disposed of in a responsible manner, in
compliance with all applicable standards and regulations (local, state,
country, federal, etc.).
The ambient air around the dryer and compressor shall not contain solid
or gaseous contaminants. All compressed and condensed gases can
generate acids or chemical products which may damage the compressor or
components inside the dryer. Take particular care with sulphur, ammonia,
chlorine and installations in marine environments.
80447162 Rev B
Table 3 : Acceptable Limits for Cooling Water Constituents
Test Interval
(Brazed Plate Heat Exchanger)
Monthly
Monthly
Monthly
Monthly
Weekly
Monthly
Monthly
Monthly
Monthly
Monthly
Monthly
The standard compressor package is designed for the following conditions:
Ingersoll Rand off ers the following options for fi xed speed compressors that
extend the environmental limits:
ACCEPTABLE MAXIMUM LIMITS
Fresh Water
0 to 1
<1
<2
<80
<0.01
<0.1
<0.3
<100
<5
<30
<70

Environmental Limits

Indoors only
Area not considered to be a high dust area.
Ambient temperature range 2 to 46 °C (5-115 °F)
Outdoor modifi cation
Low ambient option (-23 to 46 °C / -15 to 115 °F) at sea level
High ambient option (2 to 55 °C / 5 to 13 1 °F) at sea level
High dust air fi lter
High dust package fi lter
Dirty Water / Sea Water
(Shell & Tube Heat Exchanger)
-0.5 to 2.5
<2
<5
<1000
<0.5
<3
<2
<125
<5
<100
<250
EN
EN-9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

R37R45R55R75R90R110 ... Afficher tout

Table des Matières