R5.5 To 37 Kw Variable Speed Modbus Table - Ingersoll Rand R30 Information De Produit

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

93014.15.06
EN

R5.5 to 37 kW Variable Speed Modbus Table

Register
(40XXX)
1
Status/Control
3
Package Discharge Pressure
4
Sump Pressure
10
After-cooler Discharge Pressure
12
Airend Temperature
19
Separator Pressure Drop
20
Percent Capacity
25
Motor Speed
26
Motor Current
28
DC Link Voltage
30
Motor Voltage
31
Package kW
32
kW Hours
65
Total Hours MSB
66
Total Hours LSB
98
Compressor Type
99
Service Level
100
Service Time Period
103
Dryer Installed
112
Target Pressure
113
Auto Stop Pressure
114
Immediate Stop Pressure
117
Compare Savings To
121
Communication Control ON/OFF
122
Remote Start/Stop ON/OFF
123
Power Out Restart Option (PORO) ON/OFF
124
PORO Time (seconds)
127
Scheduled Start - Day
128
Scheduled Stop - Day
129
Scheduled Start (Hour)
130
Scheduled Start (Minute)
131
Scheduled Stop (Hour)
132
Scheduled Stop (Minute)
133
Rated Pressure
251
VSD Software Version Number
255
Warning Code
256
Alarm Code History
400
Reset Web Logins
EN-58
Table 33 : R5.5 TO 37 kW Variable Speed Modbus Table
Variable
Read/Write
Range
R/W
R
R
R
R
R
R
R
R
R
R
R
R
0 – 999
R
R
R
R
0 - 2
R
1000 - 8000
R
R/W
65 - 145
R/W
(T+1)-(T+10)
R/W
ASP–(ASP+10)
R/W
0 - 2
R
R
R
R/W
10 - 600
R/W
0 - 9
R/W
0 - 9
R/W
0 – 23
R/W
0 – 59
R/W
0 – 23
R/W
0 – 59
R
R
R
R
R/W
0-1
Notes
See Figure 132
Add to (mW hours * 1000)
See FIGURE 133
0=Level 0, 1=Level 1, 2=Level 2
Increments of 1000
0 = no dryer
T = target pressure
ASP = auto stop pressure
0=Geo, 1=Mod, 2=ON/OFF
0=OFF
0=OFF
0=OFF
See Figure 133
See Figure 133
Divide by 100
See Figure 134
See Figure 134
Writing a 1 value will reset the web logins to
factory defaults. After the reset is performed
this value shall be set back to 0
80447162 Rev B

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

R37R45R55R75R90R110 ... Afficher tout

Table des Matières