Factory Settings Folder - Ingersoll Rand R30 Information De Produit

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

93014.15.06
Pages 5-6: Digital Inputs
A marked checkbox beside a digital input indicates that the input is in its
TRUE state. For example, Starter Feedback is TRUE when its input is in the
high state, where as, E-Stop is TRUE when its input is at 0Vdc.
Emergency Stop
Main Motor Overload
Fan Motor Overload
Condensate Drain Error
Remote Stop
Remote Start
Remote Lead/Lag
Remote Load Enable
Remote Load/Unload
Auxiliary Input 1
Auxiliary Input 2
Dryer High Pressure
Pages 7-8: Digital Outputs
Figure 32 : Digital Outputs
A marked checkbox beside a digital output indicates that it is energized.
Starter Contact 1
Starter Contact 2
Fan Starter Contact
Blowdown Solenoid
Modulation Solenoid
Condensate Drain
Dryer Run / Fan Run
(RO) indicates read-only values.
80447162 Rev B
Figure 31 : Digital Inputs
PORO Horn
Trip Relay
Warning Relay
Low Voltage Output 1
Low Voltage Output 2
Low Voltage Output 3
Low Voltage Output 4
NOTICE
Page 9: Analog Outputs
Figure 33 : Analog Outputs
The value for the analog outputs will be in mA.
VSD Blower Output
Analog Output 2
(RO) indicates read-only values.

Factory settings folder

This folder is for factory and service personnel. A password must be entered
on page one in order to adjust values in this folder. This folder is used for
setting parameters that are specifi c to that compressor and displaying
software information for the controller.
Page 1: Password
Figure 34 : Password
Table 17 : Password
Display Text Description
Password
Provides access to enter a valid password to gain access
to password protected parameters. The password is
entered by scrolling down to the password value and
pressing the RETURN key.
Password
This checkbox will indicate a valid password has been
entered
entered. If this checkbox is blank, a valid password has
not been entered or it has timed out. This is read only.
Password
Checking this box will enable the password time feature.
timeout
enable
Password
This timeout along with the password timeout enable
timeout
allows the user to set an adjustable amount of time
to require a valid password to be re-entered. Once
this timeout is reached re-entry of a valid password is
required.
NOTICE
EN
EN-21

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

R37R45R55R75R90R110 ... Afficher tout

Table des Matières