Problem
a) Hydraulic
Cause
overloading
a) Reduce the
pump on the pres- pump vent screw,
sure side to an
operating point
which is on the
characteristic line.
Remedy
Display
Terminal box type 1:
Auto-Reset, once the motor has cooled down the pump will automatically switch
back on.
Terminal box type 3/5:
Once the motor has cooled down the reset-button must be pressed to reset the
Fault acknow-
fault manually. The pump switch back on.
ledgement
Terminal box type 2:
In case the WSK was connected to an external switching unit, the switching unit
must be reset.
Terminal box type 4:
After tripping the motor protection system, disconnect the mains voltage. Allow the
pump to cool off for 8 to 10 minutes then switch the voltage supply back on.
Motor is switched on but fails to run.
Motor protection has switched the pump off as a result of:
b) A blockage
b) Fully remove the c) Decrease the
check and rectify
free running of
pump rotor by tur-
ning the slotted end
of the shaft with a
screwdriver.
Alternative:
Disassemble the
motor head and
check;
unblock by turning
the impeller where
necessary. If the
blockage cannot be
removed, contact
Customer Services.
Display of the LED in the terminal box type
1
2
c) An excessive
pump medium
temperature.
pump medium
temperature in
accordance with
the rating plate.
3
4
red
green
ENGLISH
d) An excessive
ambient
temperature.
d) Decrease the
ambient tempera-
ture, e.g. by insula-
ting the pipes and
fittings.
5
6
red
green
7
green
29