▶ Keep the refrigerant temperature in the pressure
equipment at least 4 K above the freezing point of
the coolant. To do so, monitor the outside temperat-
ure of pressure equipment if required.
▶ If the coolant has not been drained before: Monitor
the outside temperature closely, e. g. if water is used
as coolant the temperature must not fall below 4°C.
If the refrigerant is extracted in gaseous form and the
coolant has not been drained before:
▶ Keep the coolant circuit running.
▶ Maintain the coolant temperature at least 4 K above
the freezing point of the coolant.
▶ Monitor the coolant temperature at the extraction
point.

8.3 Disposal of the pressure equipment

The pressure equipment must be removed from the
system and completely emptied.
▶ Loosen all screwed connections.
▶ Remove the pipe bundle and the brackets.
▶ The pressure equipment consists of high-quality
components, see chapter Materials, page 33. Re-
cycle the individual parts or dispose of them prop-
erly.
52

9 Tightening torques for screwed connections

9.1 Mind when mounting or replacing

WARNING
The system is under pressure!
Serious injuries are possible.
Wear safety goggles!
Assess the risk of intervention and take appropriate
measures, for example: wear additional personal pro-
tective equipment, shut off system or shut off the valves
before and after the respective system part and depres-
surise.
Before mounting
▶ Clean threads and threaded bores carefully.
▶ Use new gaskets only!
▶ Do not oil gaskets.
▶ Flat gaskets may be moistened slightly with oil.
Admissible screwing methods
• Tighten with calibrated torque spanner to indicated
torque.
• Tighten with pneumatic impact wrench and retighten
with calibrated torque spanner to indicated torque.
• Tighten with electronically controlled angled wrench
to indicated torque.
Tolerance range of tightening torques: ±6% of nominal
value
Flange connections
▶ Tighten them crosswise and in at least 2 steps
(50/100%).

9.2 Screwed connections

Metric screws
Size
M5
M6
M8
M10
M12
M14
Case A
Case B
7 Nm
9 Nm
23 Nm
42 Nm
80 Nm
36 Nm
58 Nm
DB-200-6