Package Supplied; Ambient Conditions, Ventilation, And Mounting Position - Kollmorgen SERVOSTAR 600 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2.3.4 Package Supplied

When you order a SERVOSTAR 600 series amplifier, you will receive:
SERVOSTAR 6xx
Several mating connectors (no mating SubD)
Printed SERVOSTAR 600 Safety Guide
All documentation in PDF format on CD-ROM
Setup software DRIVE.EXE on CD-ROM
Accessories: (must be ordered separately; description see accessories manual)
SERVOSTAR 601...620: motor choke 3YL required for cable length above 25m
SERVOSTAR 640/670: mains filter 3EF and mains choke 3L always required
Motor cable and feedback cable
External brake resistor
Communications cable to the PC or Y-adapter for setting parameters of up to 6 servo amp-
lifiers from one PC
AC synchronous servomotor (linear or rotary), see specific motor manual

2.3.5 Ambient Conditions, Ventilation, and Mounting Position

Storage, hints
Transport, hints
Supply voltage tolerances
Input power
Aux. power supply
Ambient temperature in
operation
Humidity in operation
Site altitude
Pollution level
Vibrations
Noise emission
Enclosure protection
Mounting position
Ventilation
(➜ # 42)
(➜ # 42)
min 3x 230V
AC / max 3x 480V
-10%
min 3x 208V
AC / max 3x 480V
-10%
24 VDC (-0% +15%), check voltage drop
0 to +45°C (32 to 113°F) at rated data
+45 to +55°C (113 to 131°F) with power derating 2.5% / K
rel. humidity 85%, no condensation
up to 1000m a.m.s.l. without restriction
1000 — 2500m a.m.s.l. with power derating 1.5%/100m
Pollution level 2 to EN 60664-1
Class 3M1 according to IEC 60721-3-3
max. 45 dB(A)
IP 20 according to EN60529
generally vertical.
forced convection by built-in fan
Make sure that there is sufficient forced ventilation within
the switchgear cabinet.
Kollmorgen | wiki-kollmorgen.eu | December 2015
S600 Safety Guide | 2   English
+10%
, 50 Hz
+10%
, 60 Hz
47

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières