HEAT MODE - READY vs REST
In order for the spa to heat, a pump needs to circulate water through the heater. The
pump that performs this function is known as the "heater pump".
The heater pump can be either a 2-speed pump (Pump 1) or a circulation pump.
Rest Mode will only allow heating during programmed filter cycles. Since polling
does not occur, the temperature display may not show a current temperature until
the heater pump has been running for a minute or two.
CIRCULATION MODE
If the spa is configured for 24HR circulation, the heater pump generally runs
continuously. Since the heater pump is always running, the spa will maintain set
temperature and heat as needed in Ready Mode, without polling.
In Rest Mode, the spa will only heat to set temperature during programmed filter
times, even though the water is being filtered constantly when in 24HR circulation
mode.
READY-IN-REST MODE
Ready in Rest Mode appears in the display if the spa is in Rest Mode and the Jets 1
Button is pressed. The spa is supposed to be in use and it will be heated up to the
selected temperature. Meanwhile Pump 1 High can be on or off, the Pump 1 Low will
be working untill the temperature selected is reached or when one hour has passed
by. After that, the System will revert to Rest Mode. This mode can also be reset by
selecting the Heat Mode line on the Screen shown here.
FILTRATION
| TOUCH PANEL
main filtration
Using the same adjustment as Setting the Time, Filter Cycles are set using a start
time and a duration. Each setting can be adjusted in 15-minute increments. The panel
calculates the end time and displays it automatically.
The Filter Icon
the Filter Cycles.
filter cycle 2 - optional filtration
Filter Cycle 2 is OFF by default. Press "1" to view Filter 1. Press "2" once to view Filter 2.
Press "2" again to turn Filter 2 ON or OFF. When Filter Cycle 2 is ON, it can be adjusted
in the same manner as Filter Cycle 1. It is possible to overlap Filter Cycle 1 and Filter
Cycle 2, which will shorten overall filtration by the overlap amount.
purge cycles
In order to maintain sanitary conditions, as well as protect against freezing, secondary
water devices will purge water from their respective plumbing by running briefly at
the beginning of each filter cycle. (Some systems will run a certain number of purge
cycles per day, independent of the number of filter cycles per day. In this case, the
purge cycles may not coincide with the start of the filter cycle.)
If the Filter Cycle 1 duration is set for 24 hours, enabling Filter Cycle 2 will initiate a
purge when Filter Cycle 2 is programmed to begin.