Iberspa SM-USO Manuel D'utilisation Et D'installation page 26

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 116
WARNING
Pay attention to the position of the maximum consumption switch.
The Spa will not operate properly if a cable not corresponding to the
distance and power of the Spa is used, and the electrical circuits may
overheat which may cause an electrical accident. Always use cable with
the suitable section of maximum consumption. In the event of doubt
between two values, always use the cable with the greater section.
To connect the supply to the electrical panel of the Spa, locate the packing gland
positioned at one end of the electrical panel.
Make sure that there is no electric current in the connection cable (differential switch
in the OFF position).
Take the cable to the Spa electrical panel.
Open the cover of the electrical cabinet, insert the feed cable through the free side.
Attention: the indicated blue cable is neutral, and the brown cable indicates the line
or phase.
Fasten the terminals as indicated in the following diagrams and the type of electrical
supply.
Single line
BLU
BRN
GRN
230V
1 ϸ
1x32A
26
J9
K2
F6 30A
TB1
1
2
3
4
4
J33
K4
K8 30A
K1
K5
016