INSTALLATION OF THE DIFFERENTIAL
The electrical installation should incorporate a high-sensitive 2-pole
differential in the general mains input panel (the differential is not
supplied with the Spa).
014
WARNING
It is essential that the owner of the Spa tests the differential switch at least
once a month, to check its good working order.
Check that the differential is in the OFF position. Do not place the differential
in the ON position until the Spa is filled with water.
CONNECT THE ELECTRICAL CONTROL PANEL TO THE DIFFERENTIAL
SWITCH
Before carrying out any work on the Spa, make sure it is disconnected from the
mains (differential switch in the OFF position, or disconnect the cable from the mains).
Use a suitable cable from the differential switch to the electric cabinet of the Spa,
depending on the location and applicable law. The cable section will vary depending
on the Spa model and the distance of the installation.
The required kW are indicated in the appendix Technical Specifications of the Spa.
The maximum power must be considered, depending on the "High Amp" or "Low
Amp" configuration.

DIP Switch Functions

Fixed-Function DIP Switches
A1 Test Mode (normally off).
A2 In "ON" position, add one high-speed pump (or blowe) with Heater.
A3 In "ON" position, add two high-speed pumps (or 1 HS Pump and Blower) with
Heater.
A4 In "ON" position, add four high-speed pumps (or 3 HS Pumps and Blower) with
Heater.
A5 In "ON" position, enables Special Amperage Rule B. See Special Features section
under Configuration Options for functionality with your system. In "OFF" position
enables Special Amperage Rule A.
24