Wiring diagram
Tab. 3:
DIP switch functions
Installation

Electrical connection

Installing and connecting the cable
The connecting cable must be guided in the door leaf from the lock side to the hinge side. Then the cable
must be routed from the door leaf into the door frame.
1
Observe the following when routing the connecting cable:
· We recommend routing the cable within the door leaf in a suitable conduit having a minimum
diameter of 7 mm.
· Do not kink the conduit and make any necessary bends as wide as possible.
· In order to avoid damaging the cable, it may only be guided around rounded corners.
· A flexible lead cover must be mounted for the transition from door leaf to frame, whereby the cover
is firmly connected to the door leaf and frame (chapter „Electric security lock 809N", page 40).
2
Connect the cable to the electric security lock 809N as specified in the connection diagram and
according to the connection diagrams of the control system.
3
Ensure that the mains adapter matches the electric security lock 809N („Technical data", page 67).
Factor in the voltage loss over the connecting cable to ensure that the lock functions safely.
Connection (without OneSystem IO module N5950)
If the electric security lock 809N is connected without the optional OneSystem IO module N5950, a control
input is available for unlocking. Status messages are not sent
Potential-free contact
(e.g. access control system,
timer, release button)
(–)
+24 V
DIP Function
1
Hi-O-group
2
Terminating resistor
3
Buzzer
4
Fail-locked
Fail-unlocked
Connection with OneSystem IO module N5950
If the electric security lock 809N is connected to the optional OneSystem IO module N5950 („Accessories",
page 69), there are many additional options for use and control.
During operation with the IO module N5950, the function of the external control input for unlocking
(Fig. 11) is deactivated („No reaction to control signal", page 72)
Colour coding
Previous
models
Technology™ Code
gr
wt
br
bu
bk
Hi-O Technology™
Off
Yes
0
Yes
enabled
Connecting cable of the
electric security lock 809N
Hi-O
gr
ye
gn
br
wt
On
Standard
1
Off
120 Ω
On
enabled
Off
Off
enabled
EN
4 3 2 1
Off