Configuration du bus de terrain
6.3 Communication via CANopen
Indice
Sous-
Nom de l'objet
OD
indice
(hex)
(hex)
1603
Receive PDO 4 mapping Parameter
0
Number of mapped application Objects in PDO
1
PDO mapping for the first application object to be
mapped
2
PDO mapping for the second application object to
be mapped
3
PDO mapping for the third application object to be
mapped
4
PDO mapping for the fourth application object to
be mapped
1604
Receive PDO 5 mapping Parameter
0
Number of mapped application Objects in PDO
1
PDO mapping for the first application object to be
mapped
2
PDO mapping for the second application object to
be mapped
3
PDO mapping for the third application object to be
mapped
4
PDO mapping for the fourth application object to
be mapped
1605
Receive PDO 6 mapping Parameter
0
Number of mapped application Objects in PDO
1
PDO mapping for the first application object to be
mapped
2
PDO mapping for the second application object to
be mapped
3
PDO mapping for the third application object to be
mapped
4
PDO mapping for the fourth application object to
be mapped
1606
Receive PDO 7 mapping Parameter
0
Number of mapped application Objects in PDO
1
PDO mapping for the first application object to be
mapped
2
PDO mapping for the second application object to
be mapped
3
PDO mapping for the third application object to be
mapped
4
PDO mapping for the fourth application object to
be mapped
172
Variateurs de fréquence avec les Control Units CU230P-2 HVAC, CU230P-2 DP, CU230P-2 CAN
Paramètre
Type de
SINAMICS
données
Unsigned8
p8713.0
Unsigned32
p8713.1
Unsigned32
p8713.2
Unsigned32
p8713.3
Unsigned32
Unsigned8
p8714.0
Unsigned32
p8714.1
Unsigned32
p8714.2
Unsigned32
p8714.3
Unsigned32
Unsigned8
p8715.0
Unsigned32
p8715.1
Unsigned32
p8715.2
Unsigned32
p8715.3
Unsigned32
Unsigned8
p8716.0
Unsigned32
p8716.1
Unsigned32
p8716.2
Unsigned32
p8716.3
Unsigned32
Instructions de service, 01/2011, FW 4.4, A5E02430659C AD
Predefined
Accès en
Connection
écriture/
Set
lecture
0
R
0
R/W
0
R/W
0
R/W
0
R/W
0
R
0
R/W
0
R/W
0
R/W
0
R/W
0
R
0
R/W
0
R/W
0
R/W
0
R/W
0
R
0
R/W
0
R/W
0
R/W
0
R/W