Charging cable cannot be unplugged
If the charging plug cannot be removed, e.g. after a power
failure, the charging plug could not be unlocked in the
device. The charging plug cannot be removed and must
be unlocked manually.
f Have the charging plug unlocked by a qualified electri-
cian via the emergency unlock function.
Î "9.3 Unlock the charging plug"
7.3

Multifunction button

For versions Professional+ 7,4 / 22 (PnC) only.
7.3.1 Restarting residual current device and circuit
breaker
Fig. 19: Restarting residual current device and circuit
breaker
f Press the multifunction button up to the end position
(> 15 mm).
Residual current device and miniature circuit breaker
9
are switched on again.

7.3.2 Checking the residual current device

Fig. 20: Checking the residual current device
f Insert a flat screwdriver with a blade width of 8 to
10 mm into the slot of the multifunction button.
f Turn the multifunction button 90° counterclockwise.
f Press the multifunction button for about two seconds
( > 5mm).
Is the residual current device functional:
9
The residual current device triggers.
9
The fault indicator on the LED info field flashes red.
f Switch the residual current device on again.
Î "7.3.1 Restarting residual current device and circuit
breaker"